Applies to SnapCenter Plug-in for VMware vSphere (SCV) 4.4 VMware Virtual SAN (VSAN) Issue Create Resource Group or Edit Resource Group gets stuck in initializing when clicking Next on page General in...Applies to SnapCenter Plug-in for VMware vSphere (SCV) 4.4 VMware Virtual SAN (VSAN) Issue Create Resource Group or Edit Resource Group gets stuck in initializing when clicking Next on page General info & notification VM Restore wizard receives the following error when clicking Next in page Select scope Example:
The backup stage completes successfully but shows the Warning status in the SCV Job Monitor Retention fails with the following error in the SCV Job Details window: Error: Unable to perform backup rete...The backup stage completes successfully but shows the Warning status in the SCV Job Monitor Retention fails with the following error in the SCV Job Details window: Error: Unable to perform backup retention on the SnapCenter server: Error writing to server The wfe_<jobID>.log will show the error: Activity (Backup Retention) of Workflow (WorkflowExecutor), Failed with error: Unable to perform backup retention on SnapCenter server: Error writing to server
Applies to SnapCenter Plug-in for VMware vSphere (SCV) 4.4 VMWare vSphere 6.5 VMWare vSphere 6.7 Issue After installing SCV 4.4 on vCenter Server, vSphere Web Client (Flash/Flex client) shows error: A...Applies to SnapCenter Plug-in for VMware vSphere (SCV) 4.4 VMWare vSphere 6.5 VMWare vSphere 6.7 Issue After installing SCV 4.4 on vCenter Server, vSphere Web Client (Flash/Flex client) shows error: An Internal error has occurred - Unable to load resource module from /ui/scvmUI/locales/com_netapp_scvmUI_en_US.properties Even tasks unrelated to SCV cannot be used via vSphere Web Client (Flash/Flex client).
Applies to SnapCenter Plug-in for VMware vSphere (SCV) versions 5.0, 6.0, 6.0.1 VMware vCenter Server (VC) Issue SCV retention applied as expected for primary and secondary storage Snapshots older tha...Applies to SnapCenter Plug-in for VMware vSphere (SCV) versions 5.0, 6.0, 6.0.1 VMware vCenter Server (VC) Issue SCV retention applied as expected for primary and secondary storage Snapshots older than retention still visible under SCV plug-in Issue can also be seen when doing a Virtual Machine (VM) restore where all secondary snapshots are available