Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 6 results
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/What_is_the_raw_block_and_metadata_capacity_for_SolidFire_and_H-Series_nodes
      ​ ​ ​ Applies to NetApp SolidFire NetApp HCI Answer Model Drive size (GB) Metadata drives Block drives Raw metadata capacity (GB) Raw block capacity (GB) Usable metadata capacity (GB) MaxProvisionedSp...​ ​ ​ Applies to NetApp SolidFire NetApp HCI Answer Model Drive size (GB) Metadata drives Block drives Raw metadata capacity (GB) Raw block capacity (GB) Usable metadata capacity (GB) MaxProvisionedSpace (bytes) SF2405 2160 108025834291 13827306789248 SF3010 3000 134994670387 17279317809536 SF4805 4320 216046791475 27653989308800 SF6010 5400 270057270067 34567330568576 SF9605/SF9010 8640 SF9608 SF19210 SF38410 H610S-1 432088705843 H610S-2 H610S-4 Additional Information Add your text here.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Is_it_possible_to_upgrade_the_storage_firmware_in_a_single_storage_node
      Applies to NetApp HCI Storage nodes Answer Additional Information A new node, or a node replaced, usually comes with a different firmware release than the existing nodes in the cluster. This upgrade c...Applies to NetApp HCI Storage nodes Answer Additional Information A new node, or a node replaced, usually comes with a different firmware release than the existing nodes in the cluster. This upgrade comes separately from the NetApp Element software upgrade Use the HCC to trigger the upgrade, only the nodes running a different version will be upgraded There is more detailed information in the product documentation
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/Failed_drive_on_Element_cluster
      Alert for driveFailed on Element cluster in NetApp SolidFire Active IQ and in cluster alerts tab
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_determine_uncorrectable_memory_errors_on_NetApp_SolidFire_and_NetApp_HCI_storage_nodes
      Applies to NetApp SF-Series Nodes NetApp H-Series Nodes Description The purpose of this article is to help determine if an uncorrectable memory error has been experienced on a system and a node should...Applies to NetApp SF-Series Nodes NetApp H-Series Nodes Description The purpose of this article is to help determine if an uncorrectable memory error has been experienced on a system and a node should be replaced
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/AutoSupport_Message__driveFailed_on_Element_cluster
      AutoSupport Message: driveFailed on Element cluster in NetApp SolidFire Active IQ and in cluster alerts tab
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/AutoSupport_Message__Incorrect_bond_port_counts_detected
      Error found in NetApp SolidFire Active IQ on NetApp Element version pre 12.0: Incorrect bond port counts detected on the Bond[X]G interfaces of nodes: {X}