Applies to NetApp Element software Issue The replication between two volumes doesn't work, with the following message: Volume pairing is Paused. Neither volume is a target. New State = PausedMisconfig...Applies to NetApp Element software Issue The replication between two volumes doesn't work, with the following message: Volume pairing is Paused. Neither volume is a target. New State = PausedMisconfigured. Previous Active Branch State = PausedDisconnected. Previous Snapshot Branch State = PausedDisconnected.
Applies to NetApp Element software Issue One or more of the following alerts appears in NetApp SolidFire Active IQ and the Cluster Web UI: A metadata service is unhealthy and SolidFire is attempting t...Applies to NetApp Element software Issue One or more of the following alerts appears in NetApp SolidFire Active IQ and the Cluster Web UI: A metadata service is unhealthy and SolidFire is attempting to migrate data away from it.
Applies to NetApp Element software Issue RTFI fails with the error message Root drive too small (ROOT_DRIVE=”/dev/nvme0n1”ROOT_DRIVE_SIZE_GB=”7” ROOT_DRIVE_SIZE_GB_MIN=”40”)
Applies to NetApp Element software NetApp HCI NetApp Deployment Engine (NDE) Answer Yes, it is supported Additional Information The Element software version that is included with the HCI version can b...Applies to NetApp Element software NetApp HCI NetApp Deployment Engine (NDE) Answer Yes, it is supported Additional Information The Element software version that is included with the HCI version can be found here
Applies to NetApp Element Plug-in for vCenter vSphere Client v5.0 Issue After expanding a Datastore, the element software does not properly report the increase of capacity. No errors are reported.
The metadata was reduced from fixed space to thin-provisioned space in Netapp Element software 6, which enables the potential to provision about 16 times the amount of space because the metadata size ...The metadata was reduced from fixed space to thin-provisioned space in Netapp Element software 6, which enables the potential to provision about 16 times the amount of space because the metadata size is no longer fixed. To calculate the provisioned space for a node, you need the usable metadata capacity per drive in bytes for your NetApp SolidFire node.
Applies to NetApp H610S Storage Node Issue WebUI shows drive locations swapped. Example: WebUI shows drive that is physically in slot 10 as slot 11 and drive that is physically in slot 11 as slot 10.
Applies to NetApp Element software Multiple Disk Slice Service (MDSS) node Description This article describes how to remove a metadata drive in an MDSS environment
Applies to NetApp SolidFire Active IQ NetApp Element software upgrade Issue SolidFire Active IQ still showing old NetApp Element software after the upgrade completed
Applies to NetApp HCI NetApp SolidFire NetApp Element software Answer No, it's not possible to recover a password or a deleted Cluster user account Additional Information The same username and passwor...Applies to NetApp HCI NetApp SolidFire NetApp Element software Answer No, it's not possible to recover a password or a deleted Cluster user account Additional Information The same username and password can be used to create a new account
Applies to NetApp Element Software NetApp HCI H Series SF Series Baseboard Management Controller (BMC) Intelligent Platform Management Interface (IPMI) Issue Access to the BMC Web UI via browser is un...Applies to NetApp Element Software NetApp HCI H Series SF Series Baseboard Management Controller (BMC) Intelligent Platform Management Interface (IPMI) Issue Access to the BMC Web UI via browser is unstable Ping results to the BMC IP's vary randomly between success and failure