    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/In_Band_ACP_reporting_initializing_firmware_update_required_or_unsupported_for_IOM6_modules
      Mon Aug 05 10:07:15 CEST [CLUSTER-01: dsa_worker1: ses.status.ACPWarn:error]: DS4246 (S/N SHFxxxxxxxxxxxx) shelf 1 on channel 0a ACP Processor warning for SAS shelf ACP processor 1: ACP status not ava...Mon Aug 05 10:07:15 CEST [CLUSTER-01: dsa_worker1: ses.status.ACPWarn:error]: DS4246 (S/N SHFxxxxxxxxxxxx) shelf 1 on channel 0a ACP Processor warning for SAS shelf ACP processor 1: ACP status not available. This module is on the rear of the shelf at the top center, on shelf module A. Mon Aug 05 10:07:16 CEST [CLUSTER-01: sem_broker: acp.need.firmware.update:error]: ACP module (NA) needs a firmware upgrade, (disk shelf serial number: SHFxxxxxxxxxxxx).
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/ATTO_Bridge_Unexpected_Reboot__Security_scanner_causing_stale_TCP_connections
      Applies to ONTAP 9.5 ATTO Bridge 7500 Platform ATTO Firmware 3.05 Issue Bridge Unexpected Reboot: Security scanner causing stale TCP connections
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/IOM6_modules_with_ACP_in_updating_firmware_status_for_a_mix_of_OoB_and_IB_ACP
      Shelves with IOM6 modules running firmware 2.10 or later Nodes configured as ACP Out-of-Band (OoB) Nodes not capable of ACP OoB (no e0P port), just In-Band (IB). A cluster with different controller mo...Shelves with IOM6 modules running firmware 2.10 or later Nodes configured as ACP Out-of-Band (OoB) Nodes not capable of ACP OoB (no e0P port), just In-Band (IB). A cluster with different controller models and shelves with IOM6 modules, show ACP "updating-firmware". Example: ::> storage shelf acp module show -fields module-name,protocol-version,firmware-version,shelf-serial-number,iom-type,state node_name 5.1.A 1.2.02.10 02.10 SHFHU1641000xxx iom6 updating-firmware
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/No_In-Band_ACP_after_adding_shelves_with_IOM12_in_an_Out-of-Band_cluster
      Shelves with 6Gbps I/O Modules (IOM6) Shelves with 12Gbps I/O Modules (IOM12) Cluster configured in Out-of-Band ACP with IOM6 shelves node_1 2.12.B 1.2.02.10 02.10 iom6 active node_1 2.12.A 1.2.02.10 ...Shelves with 6Gbps I/O Modules (IOM6) Shelves with 12Gbps I/O Modules (IOM12) Cluster configured in Out-of-Band ACP with IOM6 shelves node_1 2.12.B 1.2.02.10 02.10 iom6 active node_1 2.12.A 1.2.02.10 02.10 iom6 active node_1 2.11.B 1.2.02.10 02.10 iom6 active node_1 2.11.A 1.2.02.06 02.06 iom6 active node_2 2.12.B 1.2.02.10 02.10 iom6 active node_2 2.12.A 1.2.02.10 02.10 iom6 active node_2 2.11.B 1.2.02.10 02.10 iom6 active node_2 2.11.A 1.2.02.06 02.06 iom6 active