Applies to Fabric MetroCluster Brocade switches FabOS releases prior to 8.2.3 Issue MAPS on one or more switches reports errors similar to the below: [MAPS-1003], 4123, FID 128, WARNING, switch1, Chas...Applies to Fabric MetroCluster Brocade switches FabOS releases prior to 8.2.3 Issue MAPS on one or more switches reports errors similar to the below: [MAPS-1003], 4123, FID 128, WARNING, switch1, Chassis, Condition=CHASSIS(CPU>=80.00), Current Value:[CPU, 98.00 %], RuleName=defCHASSISCPU_80, Dashboard Category=Switch Resource.
2023/02/23-01:41:34:983319, [PLAT-5093], 1443441/0, SLOT 1 | CHASSIS, INFO, switch, Core Blade Power fail Slot 7 pwr_fail 0x30 pwr_fail_msk 0x33 , modular_ctrl.c, line: 3132, comp:emd, ltime:2023/02/2...2023/02/23-01:41:34:983319, [PLAT-5093], 1443441/0, SLOT 1 | CHASSIS, INFO, switch, Core Blade Power fail Slot 7 pwr_fail 0x30 pwr_fail_msk 0x33 , modular_ctrl.c, line: 3132, comp:emd, ltime:2023/02/23-01:41:34:983148 There aren't any core files that points to a software problem or other clues to point at a hardware issue for either unit and these events happened at roughly the same time on both units, which looks like a power event.
Applies to Brocade Fabric Operating System (FOS) Issue Flash storage usage exceeds 90% but is not yet at 100% Prevents upgrade due to root mount fullness. Can lead to switch panics Example: 2020/11/20...Applies to Brocade Fabric Operating System (FOS) Issue Flash storage usage exceeds 90% but is not yet at 100% Prevents upgrade due to root mount fullness. Can lead to switch panics Example: 2020/11/20-06:56:06, [MAPS-1021], 963, FID 128, WARNING, switch01, RuleName=defCHASSISFLASH_USAGE_90, Condition=CHASSIS(FLASH_USAGE>=90), Obj:Chassis [ FLASH_USAGE,90 %] has contributed to switch status MARGINAL.
Applies to Brocade FOS prior to 7.2.1c Issue Customer updates zones on switch and then hosts lose connection to multiple zones. In output of errdump -a on Brocade switch [SCN-1001], 19909, SLOT 4|FFDC...Applies to Brocade FOS prior to 7.2.1c Issue Customer updates zones on switch and then hosts lose connection to multiple zones. In output of errdump -a on Brocade switch [SCN-1001], 19909, SLOT 4|FFDC|CHASSIS, CRITITICAL, SCN queue overflow for process nsd" on standby cp
48 48 023000 id N32 No_Light FC (No Ports on Demand license) Disabled 49 49 023100 id N64 Mod_Uns FC (No Ports on Demand license) Disabled 50 50 023200 -- N64 No_Module FC (No Ports on Demand license)...48 48 023000 id N32 No_Light FC (No Ports on Demand license) Disabled 49 49 023100 id N64 Mod_Uns FC (No Ports on Demand license) Disabled 50 50 023200 -- N64 No_Module FC (No Ports on Demand license) Disabled 51 51 023300 -- N64 No_Module FC (No Ports on Demand license) Disabled 52 52 023400 id N32 No_Light FC (No Ports on Demand license) Disabled 53 53 023500 id N64 Mod_Uns FC (No Ports on Demand license) Disabled 54 54 023600 -- N64 No_Module FC (No Ports on Demand license) Disabled