Brocade G720 switch shows odd numbered ports in Mod_Uns state
Applies to
- Brocade G720
- FOS 8.x
Issue
- Brocade G720 switch shows ports 49, 53 with Mod_Uns state
Index Port Address Media Speed State Proto
==================================================
0 0 020000 id N32 No_Light FC
1 1 020100 id N32 No_Light FC
...
48 48 023000 id N32 No_Light FC (No Ports on Demand license) Disabled
49 49 023100 id N64 Mod_Uns FC (No Ports on Demand license) Disabled
50 50 023200 -- N64 No_Module FC (No Ports on Demand license) Disabled
51 51 023300 -- N64 No_Module FC (No Ports on Demand license) Disabled
52 52 023400 id N32 No_Light FC (No Ports on Demand license) Disabled
53 53 023500 id N64 Mod_Uns FC (No Ports on Demand license) Disabled
54 54 023600 -- N64 No_Module FC (No Ports on Demand license) Disabled
55 55 023700 -- N64 No_Module FC (No Ports on Demand license) Disabled
- The odd port numbers (49,51,53,55,57,59,61,63) are reported as Mod_Uns when a normal SFP+ is fitted
- This behavior is corrected starting from FOS 9.0.1