    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Panic_NVMEM_must_start_in_battery_backed_region_on_AFF_A800
      Applies to AFF A800 AFF C800 Issue During reboot (such as after a takeover or sync core), node continues to panic in boot loop: PANIC : NVMEM must start in battery backed region, start: 0x9470000000 b...Applies to AFF A800 AFF C800 Issue During reboot (such as after a takeover or sync core), node continues to panic in boot loop: PANIC : NVMEM must start in battery backed region, start: 0x9470000000 battery backed start: 0x9870000000 Additional DIMM mapped out errors in console logs prior to first panic show a mapped out NVMEM DIMM: Major Code 0x0A Minor Code 0x03 DIMM:11 mapped out. BIOS MRC mapped out DIMM. Major Code 0x14 Minor Code 0x02
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/SSH_connection_drops_on_SP_and_e0M_on_FAS8xxx_systems
      The Service Processor (SP) interface and e0M becomes inaccessible and does not respond to pings eth0 Link encap:Ethernet HWaddr 00:A0:98:5E:5E:40 inet addr:172.29.15.131 Bcast:0.0.0.0 Mask:255.255.0.0...The Service Processor (SP) interface and e0M becomes inaccessible and does not respond to pings eth0 Link encap:Ethernet HWaddr 00:A0:98:5E:5E:40 inet addr:172.29.15.131 Bcast:0.0.0.0 Mask:255.255.0.0 UP BROADCAST RUNNING MULTICAST MTU:1400 Metric:1 RX packets:655853 errors:0 dropped:103232 overruns:1 frame:0 TX packets:1802 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:78338004 (74.7 MiB) TX bytes:191305 (186.8 KiB) Interrupt:3