    • https://kb.netapp.com/on-prem/E-Series/Management-Apps-KBs/SMI-S_fails_to_discover_the_E-Series_Array
      The following Error message is seen when adding the E-Series Array: Enter CIMOM IP address:<CIMOM_IP_Address> Enter CIMOM user password:<password> Do you want to use secure connection? [y/n]:n Do you ...The following Error message is seen when adding the E-Series Array: Enter CIMOM IP address:<CIMOM_IP_Address> Enter CIMOM user password:<password> Do you want to use secure connection? [y/n]:n Do you want to use SSL certificate? [y/n]:n Get Snapshot Volume Repository Size Set Snapshot Volume Repository Size Get Snapshot Group Repository Size Set Snapshot Group Repository Size Enter storage array IP address:<E-Series_Controller_IP> Is this storage array password protected? [y/n]:n
    • https://kb.netapp.com/on-prem/E-Series/Hardware-KBs/Unreadable_sectors_on_the_E-series_platforms_on_single_drive
      The KB provides the solution when unreadable sector(s) detected data loss occurred on the E-series platforms.
    • https://kb.netapp.com/on-prem/E-Series/Management-Apps-KBs/Disk_pool_free_space_does_not_increase_after_deleting_a_thin_volume
      Applies to SANtricity Storage Manger(All versions) E5x00 E2x00 Issue Disk pool capacity doesn't Increase after deleting a thin volume from array management window.
    • https://kb.netapp.com/on-prem/E-Series/Hardware-KBs/E-series_drive_status
      Applies to E-Series systems Description Various states for drives and their meaning
    • https://kb.netapp.com/on-prem/ontap/da/SAN/SAN-KBs/Single_disk_path_on_Flex_array_with_Eseries_storage
      Applies to Flexarray running ONTAP with Eseries backend storage Issue Array lun having single disk path as shown below: cluster::> storage errors show Disk: NET-2.16 UID: 600A0980:00A1880C:0000020B:58...Applies to Flexarray running ONTAP with Eseries backend storage Issue Array lun having single disk path as shown below: cluster::> storage errors show Disk: NET-2.16 UID: 600A0980:00A1880C:0000020B:581178B6:00000000:00000000:00000000:00000000:00000000:00000000 -------------------- NET-2.16 (600a098000a1880c0000020b581178b6): This array LUN is only available on one path. Proper configuration requires two paths.
    • https://kb.netapp.com/on-prem/E-Series/SANtricity-OS-KBs/How_to_troubleshoot_when_E-series_Luns_are_not_accessible_from_the_host_end
      Applies to NetApp E-Series. Description This article describes the troubleshooting approach when LUN's are visible at the host end but cannot be accessed. We can perform basic checks from our end as t...Applies to NetApp E-Series. Description This article describes the troubleshooting approach when LUN's are visible at the host end but cannot be accessed. We can perform basic checks from our end as the LUN is visible at the host end, but may be corrupted and cannot be accessed/Unreadable