    • https://kb.netapp.com/Legacy/NetApp_HCI/Management_services_for_Element_Software_and_NetApp_HCI/SolidFire_cluster_not_reporting_after_upgrading_to_Element_11.7
      Unable to register mNode post upgrade of Element cluster to 11.7. [2020-04-28T15:40:02.924278Z]:[config_auth:98] CRITICAL:Configuring auth service failed: 403 Client Error: Forbidden for url: https://...Unable to register mNode post upgrade of Element cluster to 11.7. [2020-04-28T15:40:02.924278Z]:[config_auth:98] CRITICAL:Configuring auth service failed: 403 Client Error: Forbidden for url: https://<SVIP>/auth/api/1/configuration [2020-04-28T15:40:02.927922Z]:[mnodecfg:170] INFO:Deploying MNode services (this can take several minutes) [2020-04-28T15:40:13.959567Z]:[config_util:544] INFO:Deploying MNode services succeeded [2020-04-28T15:40:13.960345Z]:[mnodecfg:173] INFO:Deploying MNode Assets
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/SolidFire_volumes_flapping__due_to_faulty_NIC
      Applies to SolidFire storage SolidFire volumes going offline and subsequently coming online again. Similar messages can be seen in SolidFire Active IQ (AIQ) and the Element UI: The following volumes a...Applies to SolidFire storage SolidFire volumes going offline and subsequently coming online again. Similar messages can be seen in SolidFire Active IQ (AIQ) and the Element UI: The following volumes are offline. [volume_ID] - from cluster <cluster_name> Failed to send messages between nodes using the maximum configured MTU (9000). Messages between the following nodes failed: { 12 -> 3 }. Incorrect MTU settings can prevent garbage collection from running and cause performance problems.