Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 8 results
    • https://kb.netapp.com/on-prem/E-Series/Hardware-KBs/E5700A-16GB_is_reported_wrongly_instead_of_E5700A-64GB_after_replacement
      After replacement of E5700 controller E5700A-16GB is reported wrongly instead of E5700A-64GB after replacement STORAGE-ARRAY-PROFILE > CONTROLLERS shows the total RAM size is 64GB but the part number ...After replacement of E5700 controller E5700A-16GB is reported wrongly instead of E5700A-64GB after replacement STORAGE-ARRAY-PROFILE > CONTROLLERS shows the total RAM size is 64GB but the part number is E5700A-16GB Replacement part number: E5700A-16GB Part number: 111-03121+F0 Serial number: 021848027212 Date of manufacture: 3/12/20 Data Cache Total present: 57344 MB Total used: 50486 MB Location: Controller A, Bay 1 Data Cache Module Location: Controller A, Bay 2 Capacity: 32,768 MB
    • https://kb.netapp.com/on-prem/ontap/Perf/Perf-KBs/Poor_performance_and_high_CPU_usage_in_a_single_node_due_to_a_degraded_DIMM
      Number of correctable ECC since boot 60362216: Information about Correctable ECC: ECC error at DIMM-xx: CE-03-2106-18AEE039,ADDR 0x5959b3100,(Node(1), Memory controller(0), CH(0), DIMM(0), Rank(0), Ba...Number of correctable ECC since boot 60362216: Information about Correctable ECC: ECC error at DIMM-xx: CE-03-2106-18AEE039,ADDR 0x5959b3100,(Node(1), Memory controller(0), CH(0), DIMM(0), Rank(0), Bank Group(2), Bank(0x0), Row(0x52ad), Col(0x2c0)) Number of correctable ECC since boot 60427752: Information about Correctable ECC: ECC error at DIMM-xx: CE-03-2106-18AEE039,ADDR 0x8698e9d00,(Node(1), Memory controller(0), CH(0), DIMM(0), Rank(1), Bank Group(0), Bank(0x0), Row(0x7d3f), Col(0x70))
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/DIMM_error_detected_on_NSM100_from_NS224_shelf
      1 A DIMM 8GB 2666Mhz normal DIMM slot 1 in the top shelf module (A) 2 A DIMM 8GB 2666Mhz normal DIMM slot 2 in the top shelf module (A) 3 A DIMM 8GB 2666Mhz normal DIMM slot 3 in the top shelf module ...1 A DIMM 8GB 2666Mhz normal DIMM slot 1 in the top shelf module (A) 2 A DIMM 8GB 2666Mhz normal DIMM slot 2 in the top shelf module (A) 3 A DIMM 8GB 2666Mhz normal DIMM slot 3 in the top shelf module (A) 4 A DIMM 8GB 2666Mhz normal DIMM slot 4 in the top shelf module (A) 5 B DIMM 8GB 2666Mhz normal DIMM slot 1 in the bottom shelf module (B) 6 B DIMM 8GB 2666Mhz normal DIMM slot 2 in the bottom shelf module (B) 7 B DIMM 8GB 2666Mhz normal DIMM slot 3 in the bottom shelf module (B)
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/Node_DIMM_initialization_fail_error_on_NetApp_H6xx
      Applies to NetApp H610S NetApp H615C Issue ESXi host (H615C) is reachable via ICMP but shows disconnected from vCenter DIMM cannot be initialized successfully, and below IPMI events output repeatedly:...Applies to NetApp H610S NetApp H615C Issue ESXi host (H615C) is reachable via ICMP but shows disconnected from vCenter DIMM cannot be initialized successfully, and below IPMI events output repeatedly: 135 May/19/2020 08:18:10 [Warning] [POST Error] [BIOS POST Progress] 0xA258 : DIMM initialization fail. (CPU1_D0) - Asserted <<<
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/System_fails_to_boot_with_message_BIOS_detected_errors_or_invalid_configuration_in_DIMM_slot__XX
      Applies to FAS2240 FAS2552 Issue The storage systems fails to boot with the below error message and halts by itself: BIOS detected errors or invalid configuration in DIMM slot: XX Boot Loader version ...Applies to FAS2240 FAS2552 Issue The storage systems fails to boot with the below error message and halts by itself: BIOS detected errors or invalid configuration in DIMM slot: XX Boot Loader version 4.1 Copyright (C) 2000-2003 Broadcom Corporation. Portions Copyright (C) 2002-2011 NetApp CPU Type: Intel(R) Xeon(R) CPU C3528 @ 1.73GHz BIOS POST Failure(s) detected. Abort AUTOBOOT
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Can_memory_DIMM_be_replaced_in_H300_H500_H700
      Applies to H300E H300S H500E H500S H700E H700S Answer Memory for H300, H500 and H700 is not an FRU Replace the node Additional Information DIMM for H410C, H610C, H615C is FRU.
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/H610S_node_cannot_boot_with_power_cycle_error
      Node does not boot up, showing a blank screen Watchdog 2: power cycle (timer use at expiration: BIOS FRB2)- Asserted Severity Sensor Name Sensor Type Description [Information] [Power Unit] [Power Unit...Node does not boot up, showing a blank screen Watchdog 2: power cycle (timer use at expiration: BIOS FRB2)- Asserted Severity Sensor Name Sensor Type Description [Information] [Power Unit] [Power Unit] Power Off / Power Down - Deasserted [Information] [Power Unit] [Power Unit] Power Off / Power Down - Asserted [Warning] [Watchdog] [Watchdog 2] Power Cycle(Timer use at expiration: BIOS FRB2) - Asserted [Information] [Power Unit] [Power Unit] Power Off / Power Down - Deasserted
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/PANIC___ECC_error_at_DIMM_XX_Uncorrectable_Machine_Check_Error
      Controller reboots with a panic string similar to 'PANIC: ECC error at DIMM-x, Uncorrectable Machine Check Error'. This could be due to a DIMM failure or failure of the DIMM slot on the motherboard.