Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 11 results
    • https://kb.netapp.com/on-prem/Switches/Cisco-KBs/Questions_for_qualified_Cisco_cluster_and_storage_network_switches
      It is the customer responsibility to register all the switches purchased from NetApp directly with Cisco or a Cisco reseller as well change entitlements or to renew their systems to get support for th...It is the customer responsibility to register all the switches purchased from NetApp directly with Cisco or a Cisco reseller as well change entitlements or to renew their systems to get support for the switches. If the switch was purchased with Cisco's onsite replacement entitlement, a Cisco onsite field engineer can reconfigure the switch for management access, load the desired NX-OS version, and reload the RCF file if instructed to do so prior to going onsite.
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Remote_Device_ID_not_showing_in_network_port_output
      Node: moab-cluster1-02 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ a0...Node: moab-cluster1-02 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ a0a Default - up 9000 auto/10000 - - a0a-110 Default FrontEnd up 1500 auto/10000 - - a0a-160 Default Corporate up 1500 auto/10000 - - a0a-69 Default Storage up 9000 auto/10000 - - e0M Default Management up 1500 auto/1000 - - e0a Cluster Cluster up 9000 auto/10000 - - e0b Cluster Cluster up 9000 auto/…
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Questions_for_qualified_Broadcom_cluster_network_switches
      Please send a request to BroadcomBES@techdata.com, provide the part number and the serial number of each switch that you are looking to buy or check the status of the contract for, the planned time fr...Please send a request to BroadcomBES@techdata.com, provide the part number and the serial number of each switch that you are looking to buy or check the status of the contract for, the planned time frame of the purchase, your name, title/position, company name, address, and phone contact information.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Cluster_Network_port_is_functioning_at_a_lower_speed
      Applies to NetApp AFF and FAS systems ONTAP 9 Issue Cluster network port in a switch-less cluster setup is functioning at a lower speed (expected 10 G seen 100 M) refer to the Additional information s...Applies to NetApp AFF and FAS systems ONTAP 9 Issue Cluster network port in a switch-less cluster setup is functioning at a lower speed (expected 10 G seen 100 M) refer to the Additional information section for more details.
    • https://kb.netapp.com/on-prem/Switches/NetApp-KBs/HOW_TO__check_port_error_counters_on_a_NetApp_CN1610_cluster_switch
      Applies to NetApp CN1610 cluster network switch. Description Ethernet port error counters are used to diagnose cable and sfp problems on a link. Marginal links in the cluster network can degrade clust...Applies to NetApp CN1610 cluster network switch. Description Ethernet port error counters are used to diagnose cable and sfp problems on a link. Marginal links in the cluster network can degrade cluster performance, cause Out Of Quorum (OOQ), or trigger HA failover. Collecting this data is vital to the resolution of your support case.
    • https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/ONTAP_Select_or_CVO_Giveback_vetoed_because_aggr_is_being_resynced
      NetApp ONTAP Select (OTS) Cloud Volumes ONTAP (CVO) Giveback of ONTAP Select VM or Cloud Volumes ONTAP instance cannot complete and is vetoed by RAID module: Node Aggregate Giveback Status Warning: Un...NetApp ONTAP Select (OTS) Cloud Volumes ONTAP (CVO) Giveback of ONTAP Select VM or Cloud Volumes ONTAP instance cannot complete and is vetoed by RAID module: Node Aggregate Giveback Status Warning: Unable to list entries on node select-01. RPC: Couldn't make connection [from mgwd on node "select-02" (VSID: -1) to mgwd at xxx.xx.xxx.xxx] Giveback vetoed: Cannot the giveback without checks, use the Node management LIF cannot be accessed due to node being in takeover
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Cluster_network_degraded_alert_from_Cisco_C3132Q_V
      Mar 18, 2020 07:35:35 CDT HA Group Notification (CLUSTER NETWORK DEGRADED) ALERT [Nodename-01: vifmgr: vifmgr.cluscheck.droppedlarge:alert]: Partial packet loss when pinging from cluster lif Nodename-...Mar 18, 2020 07:35:35 CDT HA Group Notification (CLUSTER NETWORK DEGRADED) ALERT [Nodename-01: vifmgr: vifmgr.cluscheck.droppedlarge:alert]: Partial packet loss when pinging from cluster lif Nodename-01_clus2 (node Nodename-01) to cluster lif Nodename-02_clus2 (node Nodename-02). [Nodename-01: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif Nodename-01_clus1 (node Nodename-01) to cluster lif Nodename-02_clus2 (node Nodename-02).
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Failed_Cisco_switch_OS_upgrade
      Applies to Cisco 3132Q-V Cisco 3232 Cluster switch OS version 7.0(3)I7(5a) Issue Switch upgrade fails with error: switch_ C3132 # install all nxos bootflash:nxos.9[J.2.2.bin Installer will perform com...Applies to Cisco 3132Q-V Cisco 3232 Cluster switch OS version 7.0(3)I7(5a) Issue Switch upgrade fails with error: switch_ C3132 # install all nxos bootflash:nxos.9[J.2.2.bin Installer will perform compatibility check first. Please wait. Installer is forced disruptive Verifying image bootflash:/nxos.9.2.2.bin for boot variable "nxos". Return code 0x40450030 (Digital signature verification failed). Pre-upgrade check failed. Return code 0x40930011 (Image verification failed).
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/An_ONTAP_node_has_only_one_Cluster_LIF_configured
      Applies to ONTAP 9 Cluster Network Issue An ONTAP node has only one Cluster LIF configured following initial setup: Cluster-1::> net interface show -vserver Cluster -node Cluster-1-node01 (network int...Applies to ONTAP 9 Cluster Network Issue An ONTAP node has only one Cluster LIF configured following initial setup: Cluster-1::> net interface show -vserver Cluster -node Cluster-1-node01 (network interface show) Logical Status Network Current Current Is Vserver Interface Admin/Oper Address/Mask Node Port Home ----------- ---------- ---------- ------------------ ------------- ------- ---- Cluster Cluster-1-node01_clus1 up/up 169.254.85.157/16 Cluster-1-node01 e0a true
    • https://kb.netapp.com/on-prem/Switches/NetApp-KBs/Upgrading_Nexus_3132_cluster_network_switch_causes_it_to_drop_into_switch_boot_prompt
      Applies to Cisco Nexus 3000 series switches Issue When upgrading a Nexus 3000 series with compact or full image to release 7.0(3)I7(7) or 7.0(3)I7(8), it will reload and comes up in switch boot prompt...Applies to Cisco Nexus 3000 series switches Issue When upgrading a Nexus 3000 series with compact or full image to release 7.0(3)I7(7) or 7.0(3)I7(8), it will reload and comes up in switch boot prompt. Following error is seen: Trim files after extracting TOR files ... error while upgrading the firmware /mnt/cfg/1 dir return 32 <<<<<<<<<<<<<<<<<<<<< Config partitions are not partitioned properly.\nDisk will be re-initialized. <<<<<<<<<<<<<<<<<<<<< switch(boot)# prompt is then shown
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Cluster_LIFs_are_not_visible_in_network_interface_show_output_after_a_headswap_controller_upgrade_in_ONTAP_9
      Applies to AFF and FAS ONTAP 9 Issue A headswap controller upgrade is performed and the new node is booted however the cluster LIFs are not present in 'network interface show' output and the node is u...Applies to AFF and FAS ONTAP 9 Issue A headswap controller upgrade is performed and the new node is booted however the cluster LIFs are not present in 'network interface show' output and the node is unable to communicate with the cluster.