Applies to AFF A400, AFF C400 ASA A400, ASA C400 FAS8300, FAS8700 Description How to locate the HA interconnect ports on AFF A400, AFF C400, ASA A400, ASA C400, FAS8300 and FAS8700 storage systems.
Tue May 14 13:05:57 -0700 [scc57n13b: env_mgr: callhome.chassis.ps.rm:error]: Call home for CHASSIS POWER SUPPLY REMOVED: PS 1 Health alert for missing FRU is present on the cluster: Probable Cause: P...Tue May 14 13:05:57 -0700 [scc57n13b: env_mgr: callhome.chassis.ps.rm:error]: Call home for CHASSIS POWER SUPPLY REMOVED: PS 1 Health alert for missing FRU is present on the cluster: Probable Cause: PSU1 is not present in the chassis XXXXXXXXXX. Possible Effect: The nodes in the chassis might not function effectively or redundancy might be lost. Refer to the Hardware specification guide for more information on the position of the field-replaceable unit (FRU) and ways to check or replace it.
Applies to AFF A400 Ontap 9.7P2 INTEL AFBR-709DMZ-IN2 Issue EMS logs file with the following alerts: Wed May 06 20:25:55 +0200 [node: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0g on node node_n...Applies to AFF A400 Ontap 9.7P2 INTEL AFBR-709DMZ-IN2 Issue EMS logs file with the following alerts: Wed May 06 20:25:55 +0200 [node: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0g on node node_name is reporting a high number of observed hardware errors, possibly CRC errors. Tue May 19 00:40:02 +0200 [node: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0g on node node_name is reporting a high number of observed hardware errors, possibly CRC errors.
Applies to AFF A700, AFF A800, AFF A400 Non-dedicated RoCE capable port Configuring a non-dedicated RoCE capable port for storage use with the command storage port enable fails with the below error Cl...Applies to AFF A700, AFF A800, AFF A400 Non-dedicated RoCE capable port Configuring a non-dedicated RoCE capable port for storage use with the command storage port enable fails with the below error Cluster::> storage port enable -node node1 -port e5b Failed to determine whether port "e5b" on node "node1" can be used as a storage port. Wait a few minutes, then try the command again. The command will not be successfully executed, even if you try after few minutes.
After inserting a motherboard (listed above) into the chassis and closing the levers, the motherboard may not fully engage the backplane and will fail to boot up. After maintenance, such as a replacem...After inserting a motherboard (listed above) into the chassis and closing the levers, the motherboard may not fully engage the backplane and will fail to boot up. After maintenance, such as a replacement of a FRU (NVRAM card, NVRAM battery, RTC battery, DIMM, fan, boot device or PCIe adapter card) on the known-good motherboard, or a replacement of the motherboard itself, you could misinterpret the symptoms as a failed motherboard.