HWAssist notifyCfgFailed alert during BMC sync
Applies to
- NetApp AFF systems
- Hardware Assist (HWAssist)
Issue
- EMS alert reported on a node:
[cf.hwassist.notifyCfgFailed:ALERT]: Failed to update the hardware-assist configuration with hardware component (BMC): HWAssist not configured(4).
- The test trap failure log is available in the AutoSupport log file "
SP-MGMT-MLOG-TXT.GZ".
[kern_servprocd:info:10433] 0x80b750700: 0: NOTICE: Servprocd::BmcManager: perform_sync(): Check and perform BMC NW sync if necessary.[kern_servprocd:info:10433] 0x80982a700: 0: ERR: Servprocd::SPLogCollect: create_imp: hwassist_test_trap_via cpmi : Failed to send the test trap[kern_servprocd:info:10433] 0x80b750700: 0: NOTICE: Servprocd::BmcManager: perform_sync(): Check and perform BMC NW sync if necessary.[kern_servprocd:info:10433] 0x80b750700: 0: NOTICE: Servprocd::BmcManager: perform_sync(): Check and perform BMC NW sync if necessary.[kern_servprocd:info:10433] 0x80b750700: 0: NOTICE: Servprocd::BmcManager: perform_sync(): Check and perform BMC NW sync if necessary.
- Alert occurs once or intermittently
- BMC status shows
online
::*>system service-processor show IP FirmwareNode Type Status Configured Version IP Address------------- ---- ----------- ------------ --------- -------------------------NodeA BMC online true 18.3P2 ****NodeB BMC online true 18.3P2 ****
HWAssist status showsenabled / active / healthy
::*> storage failover hwassist show
Node
-----------------
NodeA
Partner: NodeB
Hwassist Enabled: true
Hwassist IP: ****
Hwassist Port: 4444
Monitor Status: active
Inactive Reason: -
Corrective Action: -
Keep-Alive Status: healthy
NodeB
Partner: NodeA
Hwassist Enabled: true
Hwassist IP: ****
Hwassist Port: 4444
Monitor Status: active
Inactive Reason: -
Corrective Action: -
Keep-Alive Status: healthy
HA and takeover functions operate normally