Version Firmware Mismatch After Failed Takeover on Upgrade
Applies to
- * ONTAP 9
Issue
Primary Problem:
node-1::> cluster image show-update-progress
Estimated Elapsed
Update Phase Status Duration Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks completed 00:10:00 00:01:08
ONTAP updates paused-on-error 01:32:00 01:03:25
Details:
Node name Status Status Description
-------------------- ----------------- --------------------------------------
Node-01 failed Error: Takeover failed.
Action: Use the "storage failover
show-takeover" command to view the
cause of takeover failure and the
suggested corrective actions. When
all issues are resolved, use the
"cluster image resume-update" command
to trigger takeover.
Node-02 completed
7 entries were displayed.
Paused - An error occurred in "ONTAP updates" phase. The update cannot continue
until the error has been resolved. Resolve all issues, then use the cluster
image resume-update command to resume the update.
Takeover was vetoed by raid with error:
::> storage failover show-takeover
Node Node Status Aggregate Takeover Status
---------- --------------------- -------------- -------------------------------
Node-01
Optimized takeover
by partner aborted.
aggr_1
Failed: Operation was vetoed
by raid.
Node-02
Optimized takeover
of partner aborted.
Run the command
"storage failover
show-takeover -node
Node-01" to
display the
relocation status of
the partner.
- -
3 entries were displayed.
On EMS
ERROR ses.mismatch.fw.version: The disk shelf modules on disk shelf 0b.10 are
running two different firmware versions. Disk shelf module A is running 0130,
and disk shelf module B is running 0140.