Azure CVO disk reporting failed following Azure freeze event
Applies to
- Cloud Volumes ONTAP (CVO)
- Microsoft Azure
Issue
A file system disk in the Azure CVO is reporting FAILED following an Azure freeze event
From EMS.LOG:
Fri Apr 26 08:44:58 +0000 [Cluster1-01: config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf -, Bay -, Model [PHA-DISK ], S/N [00000000xxxxxxxxxxxx]
From SYSCONFIG-A:
7 : NETAPP PHA-DISK 0001 4194.2GB 512B/sect (00000000xxxxxxxxxxxx) (Failed)
Data aggregate is offline due to failed disk. From AGGR-STATUS-R:
Aggregate aggr1 (failed, raid0, partial) (advanced_zoned checksums)
Plex /aggr1/plex0 (offline, failed, inactive)
RAID group /aggr1/plex0/rg0 (partial, advanced_zoned checksums)
RAID Disk Device Model Number Serial Number VBN Start VBN End
--------- ------ ------------ ------------- --------- -------
data 0b.6 PHA-DISK 00000000xxxxxxxxxxxx 0 xxxxxxxxxx
data 0b.11 PHA-DISK 00000000xxxxxxxxxxxx xxxxxxxxxx xxxxxxxxxx
data 0b.10 PHA-DISK 00000000xxxxxxxxxxxx xxxxxxxxxx xxxxxxxxxx
data 0b.9 PHA-DISK 00000000xxxxxxxxxxxx xxxxxxxxxx xxxxxxxxxx
data 0b.8 PHA-DISK 00000000xxxxxxxxxxxx xxxxxxxxxx xxxxxxxxxx
Raid group is missing 1 disk.