Permissions issue when creating a PVC in OpenShift
- Views:
- 22
- Visibility:
- Public
- Votes:
- 0
- Category:
- trident-openshift
- Specialty:
- snapx
- Last Updated:
- 5/26/2025, 7:05:35 AM
Applies to
- Astra Trident
- OpenShift (OCP)
Issue
- Unable to create a PVC with the error below in the OCP cluster:
Generated from csi.trident.netapp.io_trident-controller-76cbdb4dd7-cdqrx_add549e7-557a-44da-8fee-5d4cac46c526 failed to provision volume with StorageClass "<SC_name>": rpc error: code = Unknown desc = encountered error(s) in creating the volume: [Failed to create volume pvc-eb071610-9da8-4a51-ae7c-e8e6950e77d4 on storage pool <storage pool> from backend <backend_name>: backend cannot satisfy create request for volume <volume_name>: (ONTAP-NAS pool <storage pool>; error creating volume <volume_name>: error creating volume: [GET /cluster/jobs/{uuid}][403] job_get default {"error":{"code":"6","message":"not authorized for that command"}})]
- Using custom role to access the SVM.