In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

"system health subsystem show" output displays "CIFS-NDO" is in degraded state

Views:
219
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
cifs
Last Updated:

Applies to

  • ONTAP 9 and later
  • SMB3.0 and later

Issue

  • CIFS-NDO is in degraded state as per command "system health subsystem show" output:
cluster1::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health ok
CIFS-NDO degraded
 
  • EMS log shows below error:
Mon Oct 04 08:33:26 CST [cluster1: nchmd: hm.alert.raised:alert]: Alert Id = NoStandbyLifCifsNdo_Alert , Alerting Resource = SVM1 raised by monitor node-connect