Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Node fails to boot with error message "mcc.drsom.fsm.invalidState" in MetroCluster system

Views:
155
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • MetroCluster
  • ONTAP 9

Issue

A node of MetroCluster fails to boot with error message mcc.drsom.fsm.invalidState

Example:
 
NetApp Data ONTAP 9.1P2
 
Trying to mount root from msdosfs:/dev/da0s1 [ro]...
md0 attached to /X86_64/freebsd/image2/rootfs.img
Trying to mount root from ufs:/env/md0.uzip []...
mountroot: waiting for device /env/md0.uzip ...
Copyright (C) 1992-2017 NetApp.
All rights reserved.
Writing loader environment to the boot device.
Loader environment has been saved to the boot device.
*******************************
* *
* Press Ctrl-C for Boot Menu. *
* *
*******************************
Attempting to use existing varfs on /dev/nvrd1
No SVM keys found.
Firewall rules loaded.
Feb 08 22:51:22 Battery charge capacity: 3328 mA*hr. Power outage protection flash de-staging cycles: 100
Feb 08 22:52:42 [cluster:fcvi.update.link.state:notice]: FC-VI adapter: Physical link is up on port 1a.
Ipspace "ACP" created
Feb 08 22:52:42 [cluster:fcvi.update.link.state:notice]: FC-VI adapter: Physical link is up on port 1b.
Feb 08 22:52:42 [cluster:fcvi.qlgc.rmt.link.up:notice]: FC-VI adapter: Link to partner node over port 1a is up. Partner port id = 0xe8, partner node's system id = 0.
Feb 08 22:52:42 [cluster:fcvi.qlgc.rmt.link.up:notice]: FC-VI adapter: Link to partner node over port 1b is up. Partner port id = 0xe8, partner node's system id = 0.
Feb 08 22:52:42 [cluster:fcvi.qlgc.received.reject:notice]: FC-VI adapter: Connect request rejected on port 1b. QP name = Control, QP index = 1, Remote node's system id = xxxxxx.
WAFL CPLEDGER is enabled. Checklist = 0x7ff841ff
Feb 08 22:52:49 [cluster:mcc.drsom.fsm.invalidState:error]: DRSOM FSM event (set_sb_recovery_pending) generated in state (switchover_complete) will cause an invalid FSM state transition.
Uptime: 2m1s
System halting...

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support