Applies to

Trident 20.07.1 and above 

Kubernetes 1.17 and above 

iSCSI backends (ONTAP, HCI/SolidFire) 

Issue

When installing/upgrading to Trident 20.07.1 and later on Kubernetes >= 1.17, new iSCSI volumes created will not be writable if

  1. The storageClass does not specify “parameter.fsType” 

      (AND) 

  1. The pod using the requested PVC has an fsGroup enforced as part of a Security Constraint. 

 

An example podSpec would look like this: 

--- 

apiVersion: v1 

kind: Pod 

metadata: 

  name: sec-ctx-pod 

spec: 

  securityContext: 

    runAsUser: 1000 

    runAsGroup: 3000 

    fsGroup: 2000 

  volumes: 

  - name: sec-ctx-vol 

    persistentVolumeClaim: 

      claimName: san-pvc 

  containers: 

  - name: sec-ctx-demo 

    image: busybox 

    command: [ "sh", "-c", "sleep 1h" ] 

    volumeMounts: 

    - name: sec-ctx-vol 

      mountPath: /data/demo 

    securityContext: 

      allowPrivilegeEscalation: false 

 

“Permission denied” error is observed when attempting to write to a PV which has a blank fsType

Name:            pvc-b6bf10ac-6731-4b77-9963-b4d5516e4487 

Labels:          <none> 

Annotations:     pv.kubernetes.io/provisioned-by: csi.trident.netapp.io 

Finalizers:      [kubernetes.io/pv-protection external-attacher/csi-trident-netapp-io] 

StorageClass:    san-undefined-fstype 

Status:          Bound 

Claim:           default/san-pvc 

Reclaim Policy:  Delete 

Access Modes:    RWO 

VolumeMode:      Filesystem 

Capacity:        100Mi 

Node Affinity:   <none> 

Message: 

Source: 

    Type:              CSI (a Container Storage Interface (CSI) volume source) 

    Driver:            csi.trident.netapp.io 

    FSType:             

    VolumeHandle:      pvc-b6bf10ac-6731-4b77-9963-b4d5516e4487 

    ReadOnly:          false 

    VolumeAttributes:      backendUUID=115dc924-de93-4c8c-91be-5283c15a64f7 

                           internalName=trident_pvc_b6bf10ac_6731_4b77_9963_b4d5516e4487 

                           name=pvc-b6bf10ac-6731-4b77-9963-b4d5516e4487 

                           protocol=block 

                           storage.kubernetes.io/csiProvisionerIdentity=1602620905373-8081-csi.trident.netapp.io 

Events:                <none> 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.