Skip to main content
NetApp Knowledge Base

QoSSIOC service on mNode for VVOLs

Views:
97
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

Applies to

NetApp Element software

Answer

  • SIOC only works with standard iSCSI datastores.
  • It does not work with VVOLs.
  • The job of SIOC is to adjust QOS values on standard iSCSI SolidFire volumes when virtual machine events occur, such as power on/off and guest restart/shutdown.
  • The VASA provider on the storage array is required for VVOLS. VASA is a standard part of Element.
  • VCP and SIOC are not required for VVOLS.
  • Enabling VVOLS on the storage cluster and registering the storage cluster VASA URL with vCenter is required for VVOLS.

Additional Information

additionalInformation_text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.