Filesystem issue leads to sensorReadingFailed and nodeoffline on SolidFire node
Applies to
- NetApp SolidFire Storage
- NetApp Element Software
Issue
- The below alert is detected in the beginning:
sensorReadingFailed IPMI diagnostics are currently unresponsive. Please contact support if this problem persists.
- Then
nodeoffline
is detected and above alert is resolved:
nodeOffline The SolidFire Application cannot communicate with Storage node having node ID X.
unresponsiveService A master service is not responding.
driveFailed 12 drive(s) with state: "NodeOffline" driveID: xx, xx, xx, xx, xx, xx, xx, xx, xx, xx, xx, xx.
- Other symptoms:
- BMC web UI access has no problem
- Node UI access is unavailable
- Drive remove reports error:
RemoveDrives Failed: cannot remove driveID xx - still associated with serviceID xx
- Node console reports
EXT4-fs
related error: