Skip to main content
NetApp Knowledge Base

PowerSupply on switch is missing or is not operational

Views:
1,253
Visibility:
Public
Votes:
1
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • Cluster Network Switch

Issue

  • Power supply issue reported on cluster network switch
  • Cluster Switch Health Monitoring (CSHM) reports following health alert
"PowerSupply" on switch "switch name" is missing or is not operational.
  • EMS messages observed

[netapp-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerFail_Alert , Alerting Resource = switch name/PowerSupply raised by monitor cluster-switch
[netapp-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchPowerFail_Alert[switch name/PowerSupply].

  • Switch logs indicate PSU issue
# show environment
Fan:
---------------------------------------------------------------------------
Fan             Model                Hw     Direction       Status
---------------------------------------------------------------------------
Fan1(sys_fan1)  NXA-FAN-30CFM-F      --     back-to-front   Ok
Fan2(sys_fan2)  NXA-FAN-30CFM-F      --     back-to-front   Ok
Fan3(sys_fan3)  NXA-FAN-30CFM-F      --     back-to-front   Ok
Fan4(sys_fan4)  NXA-FAN-30CFM-F      --     back-to-front   Ok
Fan_in_PS1      --                   --     back-to-front   Shutdown
Fan_in_PS2      --                   --     back-to-front   Ok
Fan Zone Speed: Zone 1: 0x9a
Fan Air Filter : NotSupported

Power Supply:
Voltage: 12 Volts
Power                      Actual             Actual        Total
Supply    Model            Output             Input      Capacity       Status
                           (Watts )           (Watts )     (Watts )
-------  ----------  ---------------  ------  ----------  --------------------
1        NXA-PAC-650W-PE         0 W                0 W         0 W   Shutdown
2        NXA-PAC-650W-PE       162 W              174 W       650 W      Ok

Chassis has 2 PowerSupply Slots
---------------------------------------
PS1 fail/shutdown
Power supply type is: 7005.60W 220v AC
Model number is N2200-PAC-400W
H/W version is 1024.0
Part Number is 341-0375-07
Part Revision is A0
Manufacture Date is Year 2016 Week 22
Serial number is XXXXXXXXXXX

# show environment power input

Power Supply
Input:
----------------------------------------------------------
PS  Voltage    Current    Power      Status
    (Volt)     (Amp)
    (Watt)
----------------------------------------------------------
1   --         --         --         fail/shutdown
2   228.00
    1.47       334.88     ok
----------------------------------------------------------
                   Total: 334.88
  • Corrective actions recommended by health alert were carried out

Cluster::> system health alert definition show -node <node name> -monitor cluster-switch -alert-id SwitchPowerFail_Alert

                      Node: Node01
                   Monitor: cluster-switch
            Class of Alert: SwitchPowerFail_Alert
         Severity of Alert: Major
            Probable Cause: Power_supply_failure
Probable Cause Description: "$(cluster_switch_power.psu-name)" on switch "$(cluster_switch_power.device)" is missing or is not operational.
           Possible Effect: Power supply redundancy on switch "$(cluster_switch_power.device)" might be lost.
        Corrective Actions: 1) Ensure that the power supply units supplying power to the switch are turned on.
                            2) Ensure that the power cord is securely connected to the power supply of the switch.

  • Power supply reseated and failed to come online

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.