Skip to main content
NetApp Knowledge Base

Is MetroCluster FC to an IP with L3 back-end transition supported?

Views:
59
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

MetroCluster FC to IP transition

Answer

No. MetroCluster IP with an L3 network at the back-end is supported since ONTAP 9.9.1, however, only four-node MetroCluster configurations are supported (two nodes at each site) and the FC to IP transition is a 4-8-4 process.
A subsequent non-disruptive migration from L2 to L3 back-end is also not supported.
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.