Skip to main content
NetApp Knowledge Base

X477A to X336A model ID correction process - WVELE04TA07

Views:
674
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • X336A-R6 4TB NL-SAS drive
  • X336_WVELE04TA07 firmware
    • bundled in ONTAP
      • 9.10.1RC1
      • 9.9.1P3
      • 9.8P8
      • 9.6P18
      • 9.5P19

Description

Recently released ONTAP patch releases (9.10.1RC1, 9.9.1P3, 9.8P8, 9.6P18, 9.5P19) included an incorrect FW file for the X336A-R6 4TB HDD SAS drive with Model ID string X336_WVELE04TA07.

  • This FW was posted on the NetApp Support Site (NSS) for a short period of time, as well.
  • As a result, after upgrading ONTAP to this patch release or by downloading the FW from NSS, the background FW update function will download X336_WVELE04TA07.NA01.LOD firmware to the matching Model ID string mentioned above.
  • This firmware update will result in mislabeling the Model ID string being reported in ONTAP.
  • The incorrect drive string for the X336A-R6 drive will report as X477_WVELE04TA07. 

Although there is no functional issue with the Model ID string changing, it could result in an incorrect replacement drive if an RMA were issued for a failed drive.

  • The issue with the Model ID string can be corrected with the process below to revert the model ID string back without replacing the physical drive. 
  • This process will convert all the drives in the system with X477_WVELE04TA07 to X336_WVELE04TA07.

Attention: This process is to be used only on native 12Gb/s SAS3 storage with the earlier reported X336 Model ID string.

  • Do not use this process on 6Gb/s SAS2 storage that include the X477 Model ID for X477A-R6 4TB drives. Following the below process on those systems would change X477 Model ID string to X336 Product ID for the X477A-R6 drive type.
Validate

Proactive monitoring of the sysconfig -a output can identify disk drives with the incorrect ID string. 

  • Inspect the disk model ID strings of the storage shelves for any ID strings that begin with X477. 
  • Verify if the model ID is WVELE04TA07.  If the model was previously X336, then the following instructions can be used to change the ID back to X336. 
  • Do not replace any disk drives for this issue. 

::> system node run -node <name> sysconfig -a
   01.12: NETAPP X477_WVELE04TA07 NA01 4.0 TB 520B/ sect (XXXXXXXX)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.