Skip to main content
NetApp Knowledge Base

Only partial partitioned disks can be recognized on one of the node after new setup

Views:
44
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • Advanced Disk Partitioning (ADPv2)
  • AFF-C190A

Issue

  • Only 4 of partitioned disks are listed as spare disks while they are supposed to be 8 partitioned disks.
Example:
 
slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
Firmware rev:       03.08.09.00
Base WWN:           5:00a098:00e8f08:b4
Temperature:        Not Available
Phy State:          [4] Enabled, 12.0 Gb/s
[5] Enabled, 12.0 Gb/s
[6] Enabled, 12.0 Gb/s
[7] Enabled, 12.0 Gb/s
00.0 : NETAPP   X382_S164A960ATE NA53 915.4GB 520B/sect (S5NXNA0R902215)
00.1 : NETAPP   X382_S164A960ATE NA53 915.4GB 520B/sect (S5NXNA0R801601)
00.2 : NETAPP   X382_S164A960ATE NA53 915.4GB 520B/sect (S5NXNA0R902161)
00.3 : NETAPP   X382_S164A960ATE NA53 915.4GB 520B/sect (S5NXNA0R902160)
00.20: NETAPP   X382_S164A960ATE NA53 915.4GB 520B/sect (S5NXNA0R902218)
00.21: NETAPP   X382_S164A960ATE NA53 915.4GB 520B/sect (S5NXNA0R902162)
00.22: NETAPP   X382_S164A960ATE NA53 915.4GB 520B/sect (S5NXNA0R902157)
00.23: NETAPP   X382_S164A960ATE NA53 915.4GB 520B/sect (S5NXNA0R801603)
Shelf 0: DS224-12  Firmware rev. IOM12E A: 0230  IOM12E B: 0230
 
Aggregate aggr0_C190B_02 (online, raid_dp, fast zeroed) (block checksums)
Plex /aggr0_C190B_02/plex0 (online, normal, active, pool0)
RAID group /aggr0_C190B_02/plex0/rg0 (normal, block checksums)

RAID Disk        Device          HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------        ------          ------------- ---- ---- ---- ----- --------------    --------------
dparity         0b.00.0P3        0b    0   0   SA:B   0   SSD   N/A 95764/196125696   95772/196142080 (fast zeroed)
parity          0b.00.1P3        0b    0   1   SA:B   0   SSD   N/A 95764/196125696   95772/196142080 (fast zeroed)
data            0b.00.2P3        0b    0   2   SA:B   0   SSD   N/A 95764/196125696   95772/196142080 (fast zeroed)
data            0b.00.3P3        0b    0   3   SA:B   0   SSD   N/A 95764/196125696   95772/196142080 (fast zeroed)


Pool1 spare disks (empty)

Pool0 spare disks

RAID Disk        Device          HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------        ------          ------------- ---- ---- ---- ----- --------------    --------------
Spare disks for block checksum
spare           0b.00.0P1        0b    0   0   SA:B   0   SSD   N/A 409828/839327744  409836/839344128 (fast zeroed)
spare           0b.00.1P1        0b    0   1   SA:B   0   SSD   N/A 409828/839327744  409836/839344128 (fast zeroed)
spare           0b.00.2P1        0b    0   2   SA:B   0   SSD   N/A 409828/839327744  409836/839344128 (fast zeroed)
spare           0b.00.3P1        0b    0   3   SA:B   0   SSD   N/A 409828/839327744  409836/839344128 (fast zeroed)
 
Partner disks

RAID Disk        Device          HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------        ------          ------------- ---- ---- ---- ----- --------------    --------------
partner         0b.00.2P2        0b    0   2   SA:B   0   SSD   N/A 409828/839327744  409836/839344128 (fast zeroed)
partner         0b.00.0P2        0b    0   0   SA:B   0   SSD   N/A 409828/839327744  409836/839344128 (fast zeroed)
partner         0b.00.3P2        0b    0   3   SA:B   0   SSD   N/A 409828/839327744  409836/839344128 (fast zeroed)
partner         0b.00.1P2        0b    0   1   SA:B   0   SSD   N/A 409828/839327744  409836/839344128 (fast zeroed)


 
  • A new data aggregate creats failure when to specify the diskcount more than 4. 

Cluster1::> aggr create -aggregate aggr1_node2 -node node2 -diskcount 5

Error: command failed: Not enough spares on node node2.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.