How do I know if OnCommand reported latency is accurate?
Applies to
- Clustered Data ONTAP / ONTAP
- All OnCommand products
Answer
- OnCommand products obtain data directly from ONTAP which is a 5 minute average
- Any work lasting only a few seconds then going idle with high latency will not be reflected or reflected with a very slight increase
- This is the same data you can get running
qos statistics
commands orstatistics
for theworkload
object
Example: Check qos statistics
against the volume using command qos statistics volume latency show
.
Workload ID Latency Network Cluster Data Disk QoS Max QoS Min NVRAM
--------------- ------ ---------- ---------- ---------- ---------- ---------- ---------- ---------- ----------
-total- - 4.71ms 185.00us 7.00us 468.00us 4.04ms 0ms 0ms 11.00us
vol1 32140 22.22ms 86.00us 125.00us 904.00us 21.11ms 0ms 0ms 1.00us
-total- - 4.58ms 253.00us 7.00us 991.00us 3.32ms 0ms 0ms 11.00us
vol1 32140 29.69ms 90.00us 162.00us 2.61ms 26.82ms 0ms 0ms 1.00us
-total- - 2.55ms 229.00us 8.00us 589.00us 1.71ms 0ms 0ms 13.00us
vol1 32140 18.84ms 61.00us 314.00us 136.00us 18.32ms 0ms 0ms 1.00us
-total- - 4.33ms 198.00us 9.00us 1221.00us 2.88ms 0ms 0ms 13.00us
vol1 32140 177.16ms 113.00us 226.00us 108.03ms 68.79ms 0ms 0ms 2.00us
-total- - 4.09ms 233.00us 12.00us 1029.00us 2.81ms 0ms 0ms 12.00us
vol1 32140 37.79ms 215.00us 158.00us 1.84ms 35.58ms 0ms 0ms 1.00us
-total- - 3.45ms 194.00us 10.00us 780.00us 2.45ms 0ms 0ms 15.00us
vol1 32140 30.85ms 91.00us 138.00us 1169.00us 29.45ms 0ms 0ms 2.00us
-total- - 2.21ms 210.00us 6.00us 645.00us 1340.00us 0ms 0ms 11.00us
Additional Information