ESXi fails to format an FCP LUN after it is mounted

Views:
254
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

  • Brocade switches,
  • ESXi
  • All ONTAP versions

Issue

  • ESXi will fail to format an FCP LUN after it was mounted to an ESXi. Host side errors might look similar to the following:

Note: This symptom is also reported on a Cisco UCS/ Cisco MDS SAN switch/ ESXi 6.0  ESXi 6.5 environment with brocade switches.

  • Below list ESXi output

2015-02-24T20:51:24.740Z cpu18:8383)WARNING: ScsiPath: 5053: Remove path:vmhba5:C0:T2:L02015-02-24T20:51:25.092Z cpu6:11408)Vol3: 660: Couldn't read volume headerfrom control: Invalid handle 2015-02-24T20:51:25.092Z cpu6:11408)FSS: 4330:No FS driver claimed device 'control': Not supported2015-02-24T20:51:25.096Z cpu6:11408)FSS: 4330: No FS driver claimed device'naa.600a0980383030594d3f466b4d4e3379:1': Not supported 2015-02-24T20:51:25.123Z cpu6:11408)VC: 1492: Device rescan time 15 msec (totalnumber of devices 9) 2015-02-24T20:51:25.123Z cpu6:11408)VC: 1495:Filesystem probe time 42 msec (devices probed 8 of 9)2015-02-24T20:52:09.072Z cpu2:8364)ScsiScan: 1098: Path 'vmhba5:C0:T2:L0':Vendor: 'NETAPP ' Model: 'LUN C-Mode ' Rev:'8200'2015-02-24T20:52:09.072Z cpu2:8364)ScsiScan: 1101: Path 'vmhba5:C0:T2:L0':Type: 0x0, ANSI rev: 4, TPGS: 1 (implicit only)

2015-02-24T20:52:09.074Zcpu2:8364)ScsiScan: 1582: Add path: vmhba5:C0:T2:L02015-02-24T20:52:09.075Z cpu3:8384)ScsiScan: 1098: Path 'vmhba5:C0:T2:L2':Vendor: 'NETAPP ' Model: 'LUN C-Mode ' Rev:'8200'2015-02-24T20:52:09.075Z cpu3:8384)ScsiScan: 1101: Path 'vmhba5:C0:T2:L2':Type: 0x0, ANSI rev: 4, TPGS: 1 (implicit only)2015-02-24T20:52:09.075Z cpu4:8382)ScsiScan: 1098: Path 'vmhba5:C0:T2:L1':Vendor: 'NETAPP ' Model: 'LUN C-Mode ' Rev:'8200'2015-02-24T20:52:09.075Z cpu4:8382)ScsiScan: 1101: Path 'vmhba5:C0:T2:L1':Type: 0x0, ANSI rev: 4, TPGS: 1 (implicit only) 2015-02-24T22:04:33.782Zcpu1:11413)WARNING: Fil3: 2034: Failed to reserve volume f530 28 1 54eb6baed904f9e2 4b98f96a c89701e1 0 0 0 0 0 0 2015-02-24T22:04:33.809Z cpu1:11413)HBX: 4884: Marking HB [HB state abcdef04offset 3768320 gen 363 stampUS 10589636822 uuid 54eccc48-c0060174-b3e7-984be10197c8 jrnl <FB 601> drv 14.54] on vol 'svm_san2_FC_RDM1'2015-02-24T22:04:33.810Z cpu1:11413)HBX: 4962: Marked HB [HB state abcdef04offset 3768320 gen 363 stampUS 10644742072 uuid 54eccc48-c0060174-b3e7-984be10197c8 jrnl <FB 601> drv 14.54] on vol 'svm_san2_FC_RDM1'2015-02-24T22:04:33.810Z cpu1:11413)J3: 3092: Replaying journal at <FB 601>,gen 363 2015-02-24T22:04:33.820Z cpu1:11413)HBX: 3555: 1 stale HB slot(s)owned by me have been garbage collected on vol

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.