"e0M port" operational status takes time to update the status
Applies to
- FAS8200
- ONTAP 9
Issue
When a switch port is disabled or a cable removed from e0M port, its operational status is not updated to down status for approx 10 seconds.
Event appears approx 10 seconds after network cable is removed from e0M port:
mgwd log
</LR>
<LR d="30Nov2020 19:39:10" n="cluster1-01" t="1606732750" id="1606698068/982" p="6" s="Ok" o="mgmt_port_link_status_poll" vf="" type="0" seq="9636" >
<netif_linkDown_1
lanType="Ethernet"
ifName="Wrench Port"
status="down, check cable"/>
</LR>
<LR d="30Nov2020 19:39:13" n="cluster1-01" t="1606732753" id="0/25941602467974" p="5" s="Ok" o="vifmgr" vf="" type="1" seq="9637" >
<vifmgr_portdown_1
nodename="cluster1-01"
portname="e0M"/>
</LR>
<LR d="30Nov2020 19:39:13" n="cluster1-01" t="1606732753" id="0/25941602467975" p="1" s="Ok" o="vifmgr" vf="" type="1" seq="9638" >
<vifmgr_lifdown_noports_1
vifname="cluster1_01_mgmt1"
vsrvid="4294967295"
vifip="192.168.0.100"
tonode="cluster1-01"
toport="e0M"/>