  • Data ONTAP operating in 7-Mode
  • SAN environment using FCP protocol
  • Can use any host operating system supported

Answer

  • The filer will display a message in the EMS log simiilar to this:
    • [Filer:scsitarget.info:info]: SCSI BUSY : vticadapt_out_of_resources
  • This message means the Virtual Target Interconnect (VTIC) on a FCP system is being overran with partner path traffic due to multipathing misconfiguration on the host side.
  • The resolution is to fix FCP initiator configuration to point to the correct filer. The article on FCP Partner Path Misconfigured has details on what this means and how to do this.

Additional Information

Add your text here.

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.