Answer

ONTAP only sees the virtualized HW which is presented to it by the ESXi hosts.

The Failover for the uplinks in Select is not provided by ONTAP itself, but it relies on the uplinks configured in the vswitch on VMware. Normally you have an active and passive links on the vswitch and they are connected to the physical NIC of the host.

If the physical links are down on the NIC of ESXi host but the uplinks are showing as up in VMware, ONTAP will not see it and LIFs don't failover.

This is expected behavior.

Additional Information

ONTAP Select on VMware - TR 4517

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.