E-Series after drive replacement it still reports pool preservation capacity in use
Applies to
- E-Series SANtricity OS 11.50.1
- NetApp StorageGRID 11.3.x
- Controller Firmware Version 08.51.00.00
- Disk Type HUH721008AL5204 Firmware NE01
Issue
- After Drive failure and replacement the system continues to report a critical event
- Failure Entry 1:
DISK_POOL_RECONSTRUCTION_DRIVE_COUNT_BELOW_THRESHOLD-Recovery Failure Type Code: 424
- Failure Entry 1:
- Investigation does not reveal any failed drives in the disk pool