Failed Drive Cannot Be Removed from SolidFire Cluster During Element Upgrade
Applies to
- Element Software
- Element Upgrade
- H-Series Nodes
- Failed Drive
Issue
- A drive on a node fails during an Element upgrade
- Attempts to remove the failed drive using the RemoveDrives API reported success
- The drive continued to reappear in the Failed Drives list with a new drive ID
- This issue prevents the node from being removed from the cluster
- The Element upgrade halted
One or more of the following alerts may be reported in Active IQ:
hardwareConfigMismatch
Incorrect Block drive size (1.07GB) for the drive in slot X for this node type - expected 3.84TB.driveFailed11 drive(s) with state: "NodeOffline" driveID: X2, X3, X4, X5, X6, X7, X8, Y0, Y1, Y2, Y3. 1 drive(s) with state: "WrongDriveSize" driveID: Z3.driveFailed 1 drive(s) with state: "NvmeSparesExhausted" driveID:___driveHealthFault Drive with serial:___________ in slot:__, Driveshould be replaced. SMART data indicates there are no spare blocks left and it is readonly