Skip to main content
NetApp Knowledge Base

Why there could be a discrepancy in aggregate size during switchover?

Views:
163
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

​

Applies to

  • MetroCluster
  • Switchover 
  • Aggregate size difference

Answer

  • ONTAP reserves 50% of the free space to expand snap-reserve capacity in order to allow faster resync when an aggregate goes to mirror-degraded state
  • Applies if snapshot-auto-delete is turned on, so that the reserved space can be reclaimed if needed

Additional Information

How to use Snapshot Autodelete

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.