Answer

  • The following chart breaks down all states of the FC initiator adapters, and the behavior surrounding them:
Status Definition
UNINITIALIZED The firmware has not yet been loaded and initialized.
LINK NOT CONNECTED The driver has finished initializing the firmware. However, the link is not physically connected so the adapter is offline.
ONLINE The adapter is online for FC traffic.
LINK DISCONNECTED The adapter is offline due to Fibre Channel link offline event.
OFFLINE The adapter is offline for FC traffic
OFFLINE BY USER/SYSTEM A user manually took the adapter offline, or the system automatically took the adapter offline.

Additional Information

Add your text here.

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.