Applies to

  • MetroCluster IP
  • ONTAP 9
  • Environments using DWDM (Dense Wavelength Division Multiplexing) for inter-site connectivity

Issue

fter moving a MetroCluster IP (MCC-IP) to a new site, switchover operations fail. The following errors and symptoms are observed:

  • EMS log:
    EMERGENCY monitor.globalStatus.critical: Controller failover of node1-01 is not possible: unsynchronized log.
  • Switchover simulation fails:
    Cluster1::*> metrocluster switchover -simulate true[Job 40994] Job failed: Failed to validate the node and cluster components before the switchover operation. Use the "metrocluster operation show" command to view detailed error information. Resolve the errors, then try the command again.
  • metrocluster operation show output:
    Operation: switchover-simulateState: failedErrors: Failed to validate the node and cluster components before the switchover operation.Cluster1::node1-01 (non-overridable veto): DR partner NVLog mirroring is not online. Make sure that the links between the two sites are healthy and properly configured.erlh2c5a::erlh2c5a-04 (non-overridable veto): DR partner NVLog mirroring is not online. Make sure that the links between the two sites are healthy and properly configured.
  • Additional logs:
    Wed Mar 18 10:53:21+0100 [node1-02:cf_main:cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of node1-01 disabled (unsynchronized log).

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.