Object store server configuration 9.14.1 upgrade task aborted during ANDU
Applies to
- ONTAP 9
- Metrocluster-IP (MCC-IP)
Issue
- During an ANDU of a Metrocluster, an upgrade task was aborted:
::> set advanced
::*> upgrade-revert show-task-status -status aborted
name-01 2400 post-apps 2401 mgwd aborted Object store server configuration 9.14.1 upgrade and revert task