MetroCluster: LIFs placed on wrong ports after mainboard replacement, causing outage
Applies to
- MetroCluster
- Single or dual mainboard replacement while in switchover
- LIFs are placed on unusable / wrong ports after switchback leading to outage
- Data ports wrongly cabled when ONTAP booted up
Issue
When replacing a mainboard, via switchover and switchback procedure, LIFs might be placed on wrong ifgroups / ports after switching back.