Health Monitor process nchm: StorageFCAdapterFault_Alert - AutoSupport message
Applies to
- MetroCluster FC
- ONTAP 9
StorageFCAdapterFault_Alert
Event Summary
StorageFCAdapterFault alerts are generated on MetroCluster Fibre Channel systems when ONTAP health monitor detects that an FC initiator port is down.Validate
- Check the output of
system health alert show
to see the current reporting errors:
Cluster01::> system health alert show
Node: NodeA-01
Resource: 2b
Severity: Major
Indication Time: Thu Aug 05 00:06:31
Suppress: false
Acknowledge: false
Probable Cause: FC initiator adapter 2b is at fault.
Possible Effect: Resiliency of backend storage is compromised.
Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
2. Verify the operational status of the FC initiator adapter by using the command
"system node run -node local -command storage show adapter".
- Check the current status of the reporting adapter:
system node run -node <node_name> -command storage show adapter <adapter>
Cluster01::> system node run -node NodeA-01 -command storage show adapter 2b
Slot: 2b
Description: Fibre Channel Host Adapter 2b (QLogic 2532 rev. 2)
Firmware Rev: 5.4.130
FC Node Name: 2:000:0024ff:
FC Port Name: 2:100:0024ff:
FC Packet Size: 2048
Link Data Rate: 8 Gbit
SRAM Parity: Yes
External GBIC: No
State: Enabled
In Use: Yes
Redundant: Yes
- Check the switch port the adapter is connecting to: ayatem node run -node <node_name> -command sysconfig -v <adapter number>
Cluster01::> system node run -node NodeA-01 - command sysconfig -v 2
slot 2: FC Host Adapter 2b (QLogic 2532 rev. 2, N-port, <UP>)
Board name: QLE2564
Serial Number: RFD1404U12345
Firmware rev: 5.4.130
Preload Rev: 2.6.0
Host Port Id: 0x60600
FC Node Name: 2:000:0024ff:
FC Port Name: 2:100:0024ff:
SFP Vendor: FINISAR CORP.
SFP Part Number: FTLF1234P3BCV-QL
SFP Serial Number: PQH123456
SFP Capabilities: 2, 4 or 8 Gbit
Link Data Rate: 8 Gbit
Switch Port: Switch_A1:6
The highlighted section indicates the switch name and port that this adapter connects to:
- Switch name: Switch_A1
- Switch port: 6
Resolution
Identify and correct any connectivity issue between the reporting FC port and the identified switch port.
Additional Information
additionalInformation_text