Issue

  • A DISK REDUNDANCY FAILED alert was reported on MetroCluster IP.
  • Temporary loss of paths to remote disks, resulting in degraded redundancy.

Event Logs:

[Node1-01:fmmbx_instanceWorker:fmmb.redundancy.status:debug]: params: {'redundancyState':'Partial','side':'DRPartner'}
[Node1-01:svc_queue_thread:callhome.dsk.redun.fault:error]: Callhome for DISKREDUNDANCYFAILED
[Node1-01:dsa_disc:shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage
[Node1-01:dsa_disc:shelf.config.toqpha:notice]: System has transitioned to a quad-path storage configuration
[Node1-01:DR_heartbeat_thread:cf.ic.xferTimedOut:error]: HA interconnect: MCC_DRSOM transfer timed out.
[Node1-01:wafl_exempt00:nvmm.mirror.aborting:debug]: mirror of sysid2, partner_type DRPARTNER and mirror state NVMM_MIRROR_ONLINE is aborted because of reason NVMM_ERR_MIRROR_POLL_TIMEOUT.
[Node1-01:kernel:iscsi.session.stateChanged:notice]: iSCSI session state is changed to Reconnecting... Reason: no ping reply after 5 seconds.
[Node1-01:doneq0:scsi.mcc.adt.ioTransportError:error]: mcc_adt[1]-Transport error during execution of command: HAstatus0x13:CAMtransportstatus0x1b...
[Node1-01:scsi_cmdblk_strthr_admin:scsi.cmd.abortedByHost:error]: Disk device 0v.i1.1L30: Command aborted by host adapter

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.