Skip to main content
NetApp Knowledge Base

DR partner NVLog mirroring is not online during headswap procedure

Views:
434
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • Fabric MetroCluster
  • ONTAP 9
  • Headswap from AFF-A300 to AFF-A400
  • Headswap from AFF-A700/FAS9000 to AFF-A900/FAS9500

Issue

  • After finalizing the first switchback after completing the headswap for the first site in the MetroCluster, switchover simulations fail

Example:

ClusterA::*> metrocluster operation show
       Operation: switchover-simulate
           State: failed
      Start Time: 2/19/2022 22:19:52
        End Time: 2/19/2022 22:19:57
          Errors: Failed to validate the node and cluster components before the switchover operation.
                  ClusterB::ClusterB-01 (non-overridable veto): DR partner NVLog mirroring is not online.
                  ClusterB::ClusterB-02 (non-overridable veto): DR partner NVLog mirroring is not online.

  • DR mirroring is also reported to be offline despite the FCVI device status being 'up'

ClusterA::> metrocluster interconnect mirror show
                          Mirror   Mirror
                  Partner Admin    Oper
Node Partner Name Type    Status   Status  Adapter Type   Status
---- ------------ ------- -------- ------- ------- ------ ------
ClusterA-01
     ClusterA-02
                  HA      enabled  online
                                           mlx4_0  IB     Up
                                           mlx4_0  IB     Up
     ClusterB-02
                  DR      enabled  offline
                                           fcvi_device_0
                                                   FC-VI  Up
                                           fcvi_device_1
                                                   FC-VI  Up
     ClusterB-01
                  AUX     enabled  offline
                                           fcvi_device_0
                                                   FC-VI  Up
                                           fcvi_device_1
                                                   FC-VI  Up

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.