DR Config replication failed: Apply failed for Object: generate_cert
Applies to
- ONTAP 9
- MetroCluster
- DR Config Replication Autosupport generated
Issue
metrocluster vserver show
reports a degraded vserver:Vserver : svm1
Partner Vserver : svm1-mc
Configuration State : degraded
Stream Status : operation-failed
Corrective Action : Resynchronize the configuration using "metrocluster vserver resync" command. Contact technical support for assistance if configuration-state does not change to healthy.
Failed Row : Table Name: generate_cert, Operation: get, Fields: svm1-mc
Failed Reason : Apply failed for Object: generate_cert Method: baseline. Reason: duplicate entry