DR CONFIG REPLICATION FAILED - Maximum volume count for Vserver reached
Applies to
- MetroCluster
- ONTAP 9
Issue
- An autosupport is received titled DR CONFIG REPLICATION FAILED
- The output of metrocluster vserver show displays one (or more) degraded SVMs:
Cluster : ClusterA
Vserver : SVM1
Partner Vserver : SVM1-mc
Configuration State : degraded
Stream Status : processing-task
Failed Row : Table Name: volume, Operation: get, Fields: SVM1-mc ...
Table Name: volume_object_repl_attrs, Operation: get, Fields: ...
Failed Reason : Apply failed for Object: volume Method: baseline. Reason: Cannot create volume. Reason: Maximum volume count for Vserver SVM1-mc reached. Maximum volume count is 250.
Last apply fail time : 3/29/2020 12:25:41