DISK REDUNDANCY FAILED Host adapter cannot se the local ATTO and the attached disk
Applies to
- MetroCluster FC
FabricSwitchPowerFail_Alert
- Power Maintenance
- CISCO DS-C9148S-K9
Issue
- HA Group Notification from node cluster01-01
(DISK REDUNDANCY FAILED) ERROR
vsan
1
is missing inshow int port-channel 1
CISCO9148S-FAB1:>show int port-channel 1
port-channel1 is trunking
Hardware is Fibre Channel
Port WWN is 24:01:00:dx:xx:x8:x7:x0
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Port mode is TE
Port vsan is 1
Speed is 32 Gbps
Logical type is core
Trunk vsans (admin allowed and active) (10,20)
Trunk vsans (up) (10,20)
- Correct output:
Cisco9148S-FAB1# show int port-channel 1
port channel1 is trunking
Hardware is Fibre Channel
Port WWN is xx:01:8x:60:4x:20:6x:x0
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Port mode is TE
Port vsan is 1
Speed is 32 Gbps
Logical type is core
Trunk vsans (admin allowed and active) (1,10,20,50,60)
Trunk vsans (up) (1,10,20,50,60)
Trunk vsans (isolated) ()
Trunk vsans (initializing) ()