Cluster Monitoring Failed and Cluster Not Reachable reported from AIQUM
Applies to
- ActiveIQ Unified Manager (AIQUM) 9.x
- MetroCluster
- ONTAP 9.x
Issue
- Issue is related to external ZAPI calls "
storage-switch-get-iter" timing out - AIQUM is sending the ZAPI call to ONTAP and ONTAP is sending the call to the ATTO Bridges
- The issue is hit intermittently and in the failures the cause is for timeout as a resulted of a delayed response to the call
Relevant log messages:
Caused by: com.netapp.autozapi.client.ApiTimeoutException: ZAPI call storage-bridge-get-iter to netappMCC01.com timed out after 0:05:00.000 at deployment.dfm-app.war//com.netapp.autozapi.client.ZapiInvocation.invoke(ZapiInvocation.java:143) at deployment.dfm-app.war//com.netapp.autozapi.client.XmlZapiInvocation.invoke(XmlZapiInvocation.java:40) at deployment.dfm-app.war//com.netapp.autozapi.client.ZapiRunner.run(ZapiRunner.java:167) at deployment.dfm-app.war//com.netapp.autozapi.client.ZapiRunner.run(ZapiRunner.java:127) at deployment.dfm-app.war//com.netapp.dfm.ontap.outbound.zapi.ZAPIConnection.run(ZAPIConnection.java:62) at deployment.dfm-app.war//com.netapp.dfm.ontap.outbound.service.OntapMetroClusterService.fetchSwitchBridgeInfo(OntapMetroClusterService.java:223) ... 75 common frames omittedCaused by: java.net.SocketTimeoutException: Read timed out at java.base/java.net.SocketInputStream.socketRead0(Native Method) at java.base/java.net.SocketInputStream.socketRead(SocketInputStream.java:115) at java.base/java.net.SocketInputStream.read(SocketInputStream.java:168) at java.base/java.net.SocketInputStream.read(SocketInputStream.java:140) at java.base/sun.security.ssl.SSLSocketInputRecord.read(SSLSocketInputRecord.java:484)