BES switches are not visible via CDP on one or more MetroCluster IP nodes
Applies to
- MetroCluster IP
- Broadcom BES 53248
- Health Monitoring (HM)
Issue
-
In a MetroCluster IP configuration using BES-53248 switches the following HM alert may come up even if all connections to the Switch are online and
cluster peer ping
reports that all peers are reachable:
Cluster-A::*> system health alert show
Node: Node-A2
Resource: Node-A2
Severity: Major
Indication Time: Mon May 10 17:59:20 2021
Suppress: false
Acknowledge: false
Probable Cause: One or more nodes are not connected to both cluster switches.
Possible Effect: If one cluster switch fails, "Node-A2" might lose
access to the cluster.
Corrective Actions: Verify that the switch "Node-A1" is connected
to the node "Node-A2".
-
Nodes doesn't get CDP/ISDP information on cluster ports, connected to BES switch 53248:
- Command
system health alert
shows error
Cluster2::> system health alert show -fields probable-cause-description
node monitor alert-id alerting-resource probable-cause-description
---------- --------------- ------------------------------ ----------------- -------------------------------
Cluster2A ethernet-switch ClusterSwitchConnectivity_Alert
Cluster2B One or more nodes are not connected to both cluster switches.
- Devices only visible from node A, Node B not listed:
Cluster2::> network device-discovery show -node * -protocol cdp -fields port,platform
node protocol port discovered-device interface platform
-------- -------- ---- ----------------- --------- ---------
Cluster2A cdp e0a Switch01DC2 0/9 BES-53248
Cluster2A cdp e0b Switch02DC2 0/9 BES-53248