All nodes in Metrocluster report adapterHardwareErrorEMSOnly error for mediator disks
Applies to
- ONTAP 9
- MetroCluster IP
- Mediator
Issue
- All nodes in the MetroCluster report
adapterHardwareErrorEMSOnly
for the mediator disks.
[site1node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.1 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [35XXXXXXXXXXXX33] UID [35XXXXXX:XXXXXX33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.0L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c8:0008. Disk 0f.0 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [34XXXXXXXXXXXX34] UID [34XXXXXX:XXXXXX34:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.0L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.0 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [34XXXXXXXXXXXX34] UID [34XXXXXX:XXXXXX34:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:00000008:0008. Disk 0f.1 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [35XXXXXXXXXXXX33] UID [35XXXXXX:XXXXXX33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.3L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.3 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [37XXXXXXXXXXXX64] UID [37XXXXXX:XXXXXX64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c8:0008. Disk 0f.2 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [36XXXXXXXXXXXX61] UID [36XXXXXX:XXXXXX61:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.3L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c0:0008. Disk 0f.3 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [37XXXXXXXXXXXX64] UID [37XXXXXX:XXXXXX64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.2 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [36XXXXXXXXXXXX61] UID [36XXXXXX:XXXXXX61:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000
- The above errors can be seen with the Automatic Unplanned Switchover (AUSO) capability getting disabled and mediator disks reporting unhealthy.
site1node1 ERROR mcc.config.auso.stDisabled: The state of Automatic Unplanned Switchover capability has been disabled.
site1node1 ERROR cf.mccip.med.auso.stDisabled: Automatic switchover disabled: Mediator mailbox disk not healthy.
- These are reported more than once.