After re-cabling ATTO to shelves, one or more disks in local plex become unknown
Applies to
- MetroCluster
- ATTO FibreBridge 7500N
- ONTAP 9
Issue
- After re-cabling FibreBridge to shelf connections to correct mis-cabling, one or more local plexes fail.
Aggregate siteA_aggr1 (online, mixed_raid_type, mirror degraded, hybrid) (block checksums) Plex /siteA_aggr1/plex0 (offline, failed, inactive, pool0) RAID group /siteA_aggr1/plex0/rg0 (partial, block checksums, raid_dp) RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- dparity siteA-switchA1:8.126L1553 5a 10 0 FC:A 0 SAS 10000 1713523/3509295616 1716957/3516328368 parity FAILED N/A 1713523/ - data siteA-switchB2:9.126L1505 9b 10 4 FC:B 0 SAS 10000 1713523/3509295616 1716957/3516328368 ... data FAILED N/A 1713523/ - data FAILED N/A 1713523/ - data FAILED N/A 1713523/ - data FAILED N/A 1713523/ - data FAILED N/A 1713523/ - data FAILED N/A 1713523/ - Raid group is missing 15 disks.
- Disks in shelves in the connected stack report unknown container type.
- This can be true of all disks on the shelf or only some, throughout the connected stack.