Issue

  • ATTO 7600N Bridge upgrade fails with the below error:

::*> storage bridge firmware update -bridge ATTO_2000001234abcdef -uri  http://192.168.132.97/firmware.ZBD
[Job 4988] Job is queued: System bridge firmware update job.

::*> job show 4988 -instance

                      Job ID: 4988
              Owning Vserver: ClusterA
                        Name: System bridge firmware update job name
                 Description: System bridge firmware update job
                    Priority: Medium
                        Node: Node-01
                    Affinity: Cluster
                    Schedule: @now
                  Queue Time: 06/03 07:13:15
                  Start Time: 06/03 07:13:15
                    End Time: 06/03 07:13:17
              Drop-dead Time: -
                  Restarted?: false
                       State: Error
                 Status Code: 0
           Completion String: Improper response from the bridge. Wait a few minutes and try the operation again. If the error persists, contact technical support for assistance.
                    Job Type: SYSTEM_BRIDGE_FIRMWARE
                Job Category: STORAGE_JOBS
                        UUID: 37XXXXX-XXXa-XXX0-XXXf-XXXXea3bXXXX
          Execution Progress: Job error
                   User Name: admin
Restart Is Delayed by Module: -

  • Rebooting the bridge via in-band command works fine, but it does not actually reboot the bridge.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.