Skip to main content
NetApp Knowledge Base

When are "scsi.cmd.selectionTimeout" and "mlm.tapemc.lun.removed" events logged?

Views:
265
Visibility:
Public
Votes:
0
Category:
v-series-flexarray
Specialty:
san
Last Updated:

Applies to

  • Ontap 9
  • Tape drives

Answer

  • These errors/events indicate that the devices are being removed and then re-discovered.
  • These kind of messages/events are seen when a tape library/end device is rebooted.

Additional Information

Below events are logged in storage EMS:
 
Thu Jan 04 15:23:51 +0800 [NetApp: isp2400_asyncd_1: scsi.cmd.selectionTimeout:error]: Unknown device xmk91480xx:1-1.126: Adapter/target error: HA status 0x7: cdb 0x12. Targeted device did not respond to requested I/O. I/O will be retried.
Thu Jan 04 15:23:51  0800 [NetApp: isp2400_asyncd_1: mlm.tapemc.lun.removed:notice]: The tape LUN 'xmk91480xx:1-1.126L0' (S/N: 00078C2EBx) is no longer visible to this node.
Thu Jan 04 15:23:51  0800 [NetApp: isp2400_asyncd_1: mlm.tapemc.lun.removed:notice]: The medium changer LUN 'xmk91480xx:1-1.126L1' (S/N: 00000782716800xx) is no longer visible to this node.
Thu Jan 04 15:24:14  0800 [NetApp: isp2400_intrd: mlm.tapemc.lun.discovery:info]: New tape LUN xmk91480xx:1-1.126L0 (S/N: 00078C2EBx) was discovered on initiator port 0g at tape library target port WWNN: 50050760440afdxx, WWPN: 50050760444afdxy.
Thu Jan 04 15:24:14  0800 [NetApp: isp2400_intrd: mlm.tapemc.lun.discovery:info]: New medium changer LUN xmk91480xx:1-1.126L1 (S/N: 00000782716800xx) was discovered on initiator port 0g at tape library target port WWNN: 50050760440afdxx, WWPN: 50050760444afdxy.
Thu Jan 04 15:24:14  0800 [NetApp: isp2400_intrd: mlm.tapemc.path.discovery:info]: A new Tape/MC path was discovered: initiator port 0g is now connected to tape library IBM_ULT3580_1's target port: WWNN: 50050760440afdxx, WWPN: 50050760444afdxy. There are 2 LUNs visible on this target port.
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.