ONTAP SAN FC port with 500 initiator logins LIF reports waiting for link and FC transport operation timed out
Applies to
- ONTAP 9.11 and above
- Solaris
Issue
- Missing paths on host end-
20:0e:00:a0:98:xx:xx:xx MISSING NetApp NetApplif
- But on ontap end the lif is up and there areere other hosts logged in using same lif on NetApp end
- In large shared tenancy environment with high number of storage virtual machines (SVM) and LIFs with 500+ initiator logins per FC target port exceeding the FC ITN specifications may cause LIF fabric timeouts and lost paths
- Exceeding soft limit Hardware universe "Maximum Number of SAN Hosts (ITNs)" may cause fabric zoning issues and or fabric timeouts for initiators and targets
- Command
network interface show -fields status-extendedindicates one or more LIFs on FCP port are "Waiting for Link" when physical connection to switch is healthy -
Commands like
network fcp topology showandnetwork fcp zone showthrows "FC transport operation timed out" error. -
It does not give the output but throws a warning -"
Warning: Unable to list entries for kernel on node "NetApp": FC transport operation timed out."
NetApp::*> network fcp topology show -node NetApp -adapter 2a
Warning: Unable to list entries for kernel on node "NetApp": FC transport operation timed out.
Error: show failed: FC transport operation timed out
NetApp::*> network fcp zone show -node NetApp
Member Member
Zone Name Type Contents
--------------------- ------------------ ------------------- ---------------
Warning: Unable to list entries for kernel on node "NetApp": FC transport operation timed out.
Active Zone Set for adapter 2b on node NetApp
Zone Set Name: xxxxx
xyzzz Port Name xx:05:00:a0:98:xx:xx:xx
xyxxx Port Name xx:07:00:a0:98:xy:xx:xy